Heat pump water heaters

Residential and commercial heat-pump water heating with selection based on demand, recovery time and installation conditions.

Water heating & renewable energy / QATAR

Range & application

Heat pump water heaters

EcoTop residential units at 100, 200 and 300 litres with COP from 3.4 to 4.5 depending on model and air temperature, heating power 0.95–2.5kW with 1.5–2.0kW backup, R290 natural refrigerant, vitreous enamel tanks, 50mm PU insulation, 52–53 dB(A), IPX4, energy class A+, LCD touch display, automatic weekly anti-legionella cycle and optional WiFi. Aquapura Monobloc Pro at 200 and 270 litres nominal (195 and 265 usable) on R290 with GWP around 3, COP from 3.22 at 7°C to 3.94 at 20°C, published annual consumption figures at each air temperature, DHW to 65°C, 53 dB(A) sound power and 36 dB(A) at two metres, a 60 × 60cm footprint, WiFi and Modbus as standard, floor-standing or wall-mounted, with ECO, Boost and Holiday modes and a replaceable magnesium anode. Aquapura Split Green separates compressor and tank for retrofits where indoor space is tight.

Commercial and industrial systems

Aquapura Inverter X-Series high-temperature units at 30, 60 and 75kW, cascadable master-and-slave to beyond 500kW, delivering DHW to 75°C from −25°C to +43°C, COP 4.6 at 35°C and 3.5 at 55°C, R32 with twin-rotary DC inverter compressors, buffer tanks from 1,000 litres up to 50,000 in cascade, monobloc or split configuration, Modbus RTU/TCP and KNX for BMS integration, automatic thermal disinfection, and A++/A+++ energy class. Typical applications: hotels of 50–400 rooms, labour camps of 200–2,000 occupants, hospitals and clinics, industrial and food-and-beverage plants, and sports facilities. The Aquapura Booster water-to-water heat pump lifts existing 45–55°C output to full legionella-cycle temperature at up to 75°C, drawing from boreholes, geothermal loops, seawater intake, district heating return or an existing heat pump, achieving COP above 6 where source water sits between 25 and 35°C — suited to hospitals, hotels, large compounds, district hot-water schemes, industrial process water and seafront projects.

Cylinders, tanks and accessories

Thermobox storage cylinders with high-grade PU insulation, dual coil options and integrated sensor wells, compatible across the EcoTop, Monobloc Pro, Inverter and X-Series ranges. Thermobox Duo combines heating buffer and DHW cylinder in one stratified unit with a stainless coil for hygienic separation, saving plant-room footprint and capital cost, with a Duo Light variant for smaller villas and apartments. Termo XL buffer tanks to 6,000 litres with low standby losses, multiple sensor pockets and BMS-ready terminals for cascade and commercial plant rooms. Hydrokit pre-assembled hydraulic modules bring circulator, expansion vessel, safety valves, sensors and three-way valve into a wall-mounted unit installed in about an hour rather than days of plumbing — a genuine differentiator on installation cost that deserves more prominence than an accessories listing.

APPLICATION GUIDE

Where this fits your project

Heat-pump water heaters transfer heat from a source into stored water. Selection depends on the required hot-water output and recovery time as well as the air or source conditions used in the equipment rating.

Details to resolve before ordering

Review the proposed equipment location, airflow, noise, condensate drainage and electrical connection. Check performance at the intended water temperature and operating conditions, and define any backup-heating requirement for peak demand or maintenance.

Selection & project coordination

Product selection is based on the duty, installation environment and project specification. Confirm current model data, dimensions, availability and applicable documentation with the quotation.

Questions before you start

Why does recovery time matter for a heat-pump water heater?

A storage vessel can meet a short peak but still need time to recover before the next draw-off. The equipment and storage should be selected against the usage schedule, not tank volume alone.

What information is needed to quote for heat pump water heaters?

Please provide water demand profile, storage capacity, air-source location, power and recovery requirements. Include the project location, drawings or equipment schedule, required delivery date and any consultant specification. This helps our team identify the correct scope before pricing.

Can Aamtron install heat pump water heaters as well as supply them?

Supply-only and installation enquiries follow different scopes. Tell us which you need. Where installation is included, site access, supporting works, connections, testing and handover are defined separately in the quotation.

Discuss your Qatar project

Contact Aamtron’s Doha team with the project location, drawings and required programme. For occupied buildings or operating facilities, include access restrictions and permitted work windows. Product availability, delivery timing and the agreed scope are confirmed with the quotation.

Send your requirements ↗

Connected expertise

YOUR NEXT PROJECT

Bring us the challenge.
Let's build the solution.

Discuss your requirements ↗